Industrial Transmitters

Our range of products include atex transmitter, inexpensive transmitter, level switch transmitter, rh temp transmitter, hvac transmitter and universal transmitter.

ATEX Transmitter

REQUEST CALLBACK

Get Best Quote

Approx. Rs 8,500 / PieceGet Latest Price

Product Details:

Minimum Order Quantity15 Piece
BrandRotronic
Operating Range-40 to 60 Degree C / -10 to 60 Degree C
Current Consumption2x24 mA start up / 2x20 mA operation
Number Of Probe Inputs1
Start Up TimeStandard cold Less Than 60 s / warm Less Than 30 s
Measurement Interval20 to 240 s
Circuit Type2 wire
Analog Output Signal Standard4 to 20 mA, two-wire
Probe MaterialStainless steel
IP Protection RatingIP66
Dimensions160 x 100 x 61 mm
Weight1030 g / 1140 g
Accuracy Analog OutputLess Than 20 A
Power Supply10 to 28 VDC

ATEX Transmitter are supplied by us from well known vendors. Kindly find below product details of ATEX Transmitter.

Product Details:
  • Measurement of relative humidity and temperature, optional output of dew point and other calculated parameters Safe operation in areas with explosion risk
  • Intrinsically safe electrical construction
  • No intrinsically safe power supply required
  • Interchangeable stainless-steel probes
  • Robust aluminium housing

Send Bulk Enquiry

Inexpensive Transmitter

REQUEST CALLBACK

Get Best Quote

Approx. Rs 8,500 / PieceGet Latest Price

Product Details:

Minimum Order Quantity15 Piece
IP RatingIP65
Supply Voltage12 to 28 VAC / 15 to 40 VDC
ParametersHumidity and / or temperature
Housing MaterialABS
Integrated SensorsYes
Humidity SensorRotronic Hygromer IN-1
SensorThermistor
Response Time4S
Current4 to 20 mA
Voltage0 to 1/5/10 VDC

With the help of competent professionals, we have been able to offer Inexpensive Transmitter. Below are the features of Inexpensive Transmitter.

Innovative in Humidity and Temperature Measurement:

  • Measures relative humidity and temperature
  • Hygromer IN-1 humidity sensor
  • Adjustable at 35 % and 80 %RH
  • Two freely scalable analog voltage or current outputs
  • USB service interface
  • Reduced dimensions
  • Easy mechanical installation

Product Details:
Transmitter type2-wire type:HF120
¾ wire type: HF13x
Current Consumption2-Wire Type max. 40 mA
¾ Wire type
With voltage output: Less Than 15 mA
With current output: Less Than 55mA
WeightWall Version Type W And A: 140g
Duct Version 100 mm type B and D: 140 g
Duct Version 300 mm type E and F: 200 g
Space version type L and S: 90 g
Operating and measurement range-20 to 50 Degree C / 0 to 100 % RH (non-condensing)
CE / EMC compatibility2004/108/EC
Humidity Measurement
Accuracy at 23 Degree C +/- 5KLess Than 3 % ( 10 to 90 %RH)
Long-term stabilityLess than 1.5% RH per year
Response time 6330 s (63% of a jump 30 to 80 % RH) withour filter
Temperature Measurement
Standard Temperature Scale0 to 50 Degree C or 0 to 100 Degree F
Accuracy at 23 Degree C +/- 5K+/- 0.3 Degree K ( 0 to 50 Degree C)
Outputs
NumberTwo Freely scalable analog outputs

Send Bulk Enquiry

View PDF

Level Switch Transmitter

REQUEST CALLBACK

Get Best Quote

Approx. Rs 1,200 / PieceGet Latest Price

Product Details:

Accuracy0.5%Fs
IndicateFlow Rate, Total Flow
MediumLiquid, Air, Gas
Measuring Range0..6 m
Current Output4 - 20 mA (2-wire)
Voltage Output0 - 10 V (3-wire)

Capacitance Level Sensor all metals and nonmetals. The switch is used for sending level of powder, granules and liquids. Capacitance Level Sensor is low cost level sensor for powders.

Send Bulk Enquiry

Save time! Get the Best Deal

*Your information is safe with us.

RH Temp Transmitter

REQUEST CALLBACK

Get Best Quote

Approx. Rs 3,500 / PieceGet Latest Price

Product Details:

Accuracy (%)+/- 2% RH, +/- 0.5 Degree C
TypeTransmitter
IP RatingIP66
Low Loop Drop11.5 - 32 V DC loop supply
Outputs2 x 4-20 mA
Model NoSC804

Features:
  • SC804, a high-performance 2-wire Relative Humidity and Temperature (RH+T) Transmitter for use in hazardous environments. With its integral relative humidity and temperature sensor, the transmitter is inside a surface-mounted flameproof (certified for gas groups I, IIA, IIB and IIC) enclosure with an completely dust proof and can withstand temporary flooding.
  • Remote external sensors, SHT20, SHT30 (wall-mount) and SHT40 (duct-mount), may be placed as far as 25 meters from the unit.
  • SC804 has a dual LED display visible through the flameproof enclosure; the upper indicates relative humidity and the lower indicates temperature.

Send Bulk Enquiry

HVAC Transmitter

REQUEST CALLBACK

Get Best Quote

Approx. Rs 5,500 / PieceGet Latest Price

Product Details:

Minimum Order Quantity15 Piece
IP RatingIP65
WeightApprox 120g
Housing materialABS
Measurement Range-40 to 60 Degree C / 0 to 100 %rh
Change in signal TypeHF33 only
Power Supply"HF 32: 10 to 28 VDC: 10 V + (0.02 x load) HF33: 15 to 40 VDC / 12 to 28 VAC HF34: 8 to 40 VDC / 6 t

We are supplier and Trader of HVAC Transmitter. Measurement of room temperature for energy-efficient control of HVAC systems and monitoring energy consumption.
Temperature recording for heating and air-conditioning systems in dry rooms, e.g. residential, office and business premises.

Features:
  • Active measured value acquisition
  • Cable inlet at rear
  • Suitable for direct wall mounting
  • Connection of an external Ni1000 temperature sensor possible

Technical description:
  • Nickel thin-film sensor as per DIN 43760
  • Housing made of pure white flame-retardant thermoplastic (RAL 9010)
  • Screw terminals for wire of up to 1.5 mm²

Product Details:

HF32 WireHF33 ¾
-Wires
HF34
Hygro./Thermostat
Integrated SensorsYes
Humidity SensorRotronic Hygromer In-1
Temperature SensorPt100 1/3 Class B
Accuracy at 23 +/- 5 Degree C+/-2.0 %rh / 0.3 K (+/-1.0%rh / 0.2 K Type R)
Resolution air Chip 3000<0.02 %rh /year
Long-term stability humidity sensor<1% rh / year
Response time 63<10S
Electronics operating Range-40 to 60 Degree C / 0 to 100 %rh (-10 to 60 Degree C with LCD)
Display (Space version only)
(HF32s: no back light)
Graphic LCD
Parameters freely configurable
Alarm Function (programmable)Open or shorted Sensor
Output signalsFreely Scalable by user
0.1 v, 0.5 V, 0.10 V, 0(4)020 mA
Power ConsumptionHF32: max 40 mA, other models < 100 mA
Min. max. loadV-signal Greater Than or equal 1 k V/mA signal: Less Than or equal 500
firmware updateVia service connector , requires HW4 software
Sensor diagnostics (Drift, state)Programmable . Default: off
Sensor ProtectionPolyethylene filter
Max air velocity20 m/s at probe
AdjustmentsVia ROTRONIC accessories
Humidity:multi point; temperature: 2 points
Hygro. / Thermo stat2 Relays, HF34 only

Send Bulk Enquiry

View PDF

Universal Transmitter

REQUEST CALLBACK

Get Best Quote

Approx. Rs 2,500 / PieceGet Latest Price

Product Details:

Minimum Order Quantity15 Piece
WeightApprox 145 g
Storage Temperature-20 Degree C to +85 Degree C
Operating Temperature-20 Degree C to +60 Degree C
Screw Terminal Torque0.5 Nm
Sensor CurrentNormal 0.2 mA
Calibration Temperature20 to 28 Degree C
Relative HumidityLess Than 95% RH (non-cond.)
Protection DegreeIP20
Dimensions109 x 23.5 x 104 mm (H x W x D)
Wire Size1 x 2.5 mm2

We offer Universal Transmitter to our clients. Kindly find below product details of Universal Transmitter.

Advanced Features:
  • Programmable by way of detachable display front (4501), process calibration, signal simulation, password protection, error diagnostics and help text available in several languages.

    Application:
    • Linearized, electronic temperature measurement with RTD or TC sensor.
    • Conversion of linear resistance variation to a standard analog current / voltage signal, i.e. from solenoids and butterfly valves or linear movements with attached potentiometer.
    • Power supply and signal isolator for 2-wire transmitters.
    • Process control with standard analog output.
    • Galvanic separation of analog signals and measurement of floating signals.
    • The 4114 is designed according to strict safety requirements and is therefore suitable for application in SIL 2 installations.

    Technical characteristics:
    • When 4114 is used with the 4501 display / programming front, all operational parameters can be modified to suit any application. As the 4114 is designed with electronic hardware switches, it is not necessary to open the device for setting of DIP-switches.
    • A green / red front LED indicates normal operation and malfunction.
    • Continuous check of vital stored data for safety reasons.
    • 3-port 2.3 kVAC galvanic isolation.

    Common Specifications:
    Supply voltage, universal.21.6...253 VAC, 50...60 Hz or
    19.2...300 VDC
    Fuse400 mA SB / 250 VAC
    Max. required power≤ 2.0 W
    Isolation voltage, test /
    Working
    2.3 kVAC / 250 VAC
    Response time
    Temperature input (0...90%, 100...10%)≤ 1 s
    mA / V input (0...90%, 100...10%)..≤ 400 ms
    Auxiliary supplies
    2-w. supply (term. 44...43)25...16 VDC / 0...20 mA
    ProgrammingCommunication enabler 4511
    / Programming front 4501
    Signal / noise ratioMin. 60 dB (0...100 kHz)
    AccuracyBetter than 0.1% of selected
    Range
    EMC immunity influence< ±0.5% of span
    Extended EMC immunity: NAMUR
    NE21, A criterion, burst
    < ±1% of span
    Input specifications
    RTD input
    RTD typPt10/20/50/100/200/250;
    Pt300/400/500/1000;
    Ni50/100/120/1000;
    Cu10/20/50/100
    Cable resistance per wire. 50 Ω (max.)
    Effect of sensor cable resistance
    (3-/4-wire)
    < 0.002 Ω / Ω

      Send Bulk Enquiry

      View PDF
      X